Part name: HVAC Pressure Sensor
Description:
Eltek HVAC Pressure Sensor is suitable for measuring the absolute pressure of gas of the conditioning circuit. Suitable for PC-LD and MD-HD applications. Chemical resistance to the conditioning gas is guaranteed by means of approved materials. The sensitive element is a ceramic element capable of detecting the absolute pressure, integrating a signal conditioning IC, which is directly assembled on the sensor. All the active and sensing electronic circuits are not in contact with the gas and they are separated from it by a ceramic membrane. The sensor output is ratiometric with the power supply. Calibration procedure, fault conditions management, ESD and EMI requirements are guaranteed by means of an approved IC according to automotive standards.
General characteristics:
  • Temperature Compensated (3 points)
  • Pressure Compensated (2 points)
  • Custom Calibration by Conditioning IC
  • Analog or Digital Output
  • Automotive Designed
  • HV, RP and Short Circuit Protection
  • Safety and Diagnostic Functions
  • Long Term Stability
  • Low Power Consumption
  • Piezoresistive Technology (Thick Film)
  • Real Time Measure
  • Electric custom connection
  • Custom Hydraulic Port (stailess steel)
ADD TO MYPDF
TECHNICAL DRAWING
Technical data:
Accuracy ± 2% F.S 0°C... 25°C (0,3 ..25 bar)
± 2,5 % F.S 0°C... 25°C (25 ..30 bar)
± 3% F.S -5°C...0°C and 25°C...80°C (0,3 ..25 bar)
± 3,5% F.S -5°C...0°C and 25°C...80°C (25 ..30 bar)
Pressure Range 0,3 bar.........30 bar absolute
(other pressure ranges or absolute pressure available on demand)
Max Continuous Pressure 100 bar
Burst Pressure 120 bar
Operating Voltage (nominal) 5.0 ± 0,25 V
Maximum Voltage -18V....+32V
ESD (ISO 10605): ± 15KV Air discharge
± 8KV Direct contact
Diagnostic Functions output goes above
4,75V and/or below 0,3V in case of failure
Supply Current < 10 mA
Output Voltage (Vout) 0,5V....4,5 V ratiometric
Digital Standard I2C
Digital Custom OWI
Response Time from 10% to 90% <10 ms
Temperature Range -40°C....+100°C
(+ 125°C for 60 min)
Insulation Resistance min 10 MΩ
Medium Gas for conditioning circuits